

ABB drives are the best solutions that will help you save considerable energy particularly in applications such as pumps, fans and compressors. ABB drives ensure that energy is consumed only to the extent required by the process and thus reduce your energy costs.

Typical constant torque applications include mixers. The drive is suitable for industries such as food and beverage, material handling and textile. Adaptive programming offers an easy alternative for simple programming needs. Is it this 'FENA-01 adaptor' that i would need?cot201.nsf%2Fveritydisplay%2Fe009e865cd89cf0ec122472%2F%24file%2Fenfena01modbustcppmbs creenres.The world leader in technology, ABB is the top manufacturer of variable-speed motor drives with its wide range of products and technology.ĪBB low-voltage motor drives offer you the motor control solutions that you need in industrial, building and OEM sectors thanks to their safety, easy-to-use features, flexible operating conditions and long service life. ACS380-040S-07A8-1 - ABB Drives Standard drives with I/O and Modbus RTU Phase-1: 1.5HP, 240V, 6.9A.

That may be viable as i have two ethernet ports on the Beckhoff plc. I don't use Beckhoff controllers at all, but had a presentation by one of their salesmen last week and asked some questions about their serial modules.Beckhoff has two different bus types:E-Bus is extremely fast and based on EtherCAT.K-Bus is older and slower and is a Beckhoff/Wago proprietary protocol.The CX9000 controller has E-Bus.The CX9001 controller has K-Bus.The module you linked to, the KL6001, uses K-bus.To run Modbus RTU protocol on that module, you would also need a Beckhoff license for the Modbus RTU library, part number TS6255. This program contains basic ladder logic for controlling the ABB drive. You need to look carefully at the user manual bkottaras linked to, to understand which pins implement the serial port on that connector.Those RJ45 connectors on the Beckhoff CX9000 controller are Ethernet connectors.While I don't know these particular devices, it's very likely that the ACS350 drive includes power on some of the pins and will damage or destroy an Ethernet port if you were to connect them together.To connect your Beckhoff CX9000 controller to the ACS350 drive, you would need at a minimum the Beckhoff CX9000-N030 serial communication module. This example highlights how to control the ACS800, DCS800, ACS550, ACH550, ACS350 with the RPBA-01 and FPBA-01 option on PROFIBUS DP within CoDeSys. With the box in the Step column checked, the addresses on the Ignition side will index by 2. It's made to connect to their operator panels and option modules but also includes in RS-232 port that can accept commands using the Modbus RTU protocol. The Modbus address mapping below shows how to map float point addresses starting at 1024 and ending at 1030.
